Zebron ZB-WAX GC Columns
PEG Versatility for Solvents, Acids, and Amines
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron ZB-WAX GC Columns
PEG Versatility for Solvents, Acids, and Amines
- Bonded, solvent rinsable phase excellent for separating polar complex mixtures
- GC-MS Certified low bleed levels
- Low activity for amines
- Excellent separations of polar complex mixtures; widely used for profiling and “fingerprinting”
Want enhanced aqueous stability? See ZB-WAXPLUS.
Testing free fatty acids? See ZB-FFAP.
Recommended Applications
The Zebron ZB-WAX columns can be used for Alcohols, Aldehydes, Aromatics, Basic Compounds, Essential Oils, Flavors & Fragrances, Glycols, Pharmaceuticals, Solvents, Styrene, Xylene Isomers
Overview
Upgrade to Zebron from any polyethylene glycol phase:
Agilent® | Restek® | SGE | Supelco® |
|---|---|---|---|
DB®-WAXetr | Rtx®-WAX | SolGel-WAX™ | Met-Wax |
| HP-INNOWax | Famewax | Omegawax | |
| HP-20M | Stabilwax®-DB |
Performs for Industrial Chemicals
BTEX by GC-FID
Columns: | Zebron ZB-WAX |
Dimension: | 30 meter x 0.32 mm x 0.50 µm |
Part No.: | 7HM-G007-17 |
Injection: | Split 20:1 @ 250 °C, 0.2 µL |
Carrier Gas: | Helium @ 2 mL/min (constant flow) |
Oven Program: | 60 °C to 75 °C @ 15 °C/min to 90 °C @, 3 °C/min (hold 3 min) |
Detector: | FID @ 300 °C |
Sample:
1. Pentane
2. Heptane
3. Solvent (methylene chloride)
4. Benzene
5. Decane
6. Toluene
7. Ethylbenzene
8. p-Xylene
9. m-Xylene
10. Dodecane
11. o-Xylene
Documents
- Supporting Docs: Zebron Essentials Phases
- Guide: GC Troubleshooting Quick Reference Guide
- Guide: Zebron GC Column Selection Chart
- Brochures: Zebron Gas Management Brochure
- Technical Notes: Aqueuos Stability for Distilled Spirits Testing by GC (TN-2025)
- Supporting Docs: Zebron Gas Filter User Guide
- Supporting Docs: Zebron Gas Filter Selection Tool
- Technical Notes: Solvent Purity Estimation Using a Zebron ZB-624PLUS GC Column
- Technical Notes: Residual Solvents per USP 467 using Zebron ZB-624 PLUS and ZB-WAXPLUS GC Columns (TN-2074)
- Brochures: Chemical Industry LC & GC Separation Solutions Guide
- Brochures: Zebron Essentials Brochure
- Technical Notes: Considerations for Using Narrow Bore (0.10 mm) GC Columns (TN-2015)
FAQs
Can I pack or re-pack my GC liner with wool?
Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.
What are the differences between the ZB-Wax and ZB-WaxPlus?
The ZB-WaxPlus phase is made of a lower molecular weight polymer that has liquid character at lower temperature than the original ZB-Wax. The unique bonding of the lower molecular weight PEG polymer in ZB-WaxPlus allows it to be used with 100% aqueous samples, without inconsistencies from injection to injection, and gives better selectivity for low boiling point compounds. The ZB-WaxPlus tends to give better peak shape for acids while the original ZB-Wax gives better peak shape for basic compounds.
Does the Zebron PLUS liner with wool improve my GC column lifetime?
Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.
I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?
It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.
Is there a way I can get immediate help with my current and upcoming method?
Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.
I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?
For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.
When facing peak and resolution issues in sample analysis by GC, where is the best place to start?
The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.
Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?
Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.
Manufacturer information: Zebron ZB-WAX GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
Specifications for Zebron ZB-WAX GC Columns
| GC Length (m) | 10 or 15 or 20 or 25 or 30 or 40 or 50 or 60 |
| GC Internal Diameter (mm) | 0.1 or 0.18 or 0.25 or 0.32 or 0.53 |
| GC Film Thickness (µm) | 0.1 or 0.15 or 0.18 or 0.25 or 0.5 or 1 or 1.2 or 2 or 3 |
| GC Format | Capillary Column or 5-inch Cage |
| GC Option | Standard or Custom or F&F |
| Manufacturer | Phenomenex |
| GC Phase | ZB-WAX |