Zebron ZB-PAH-EU GC Columns

  • Manufacturer
  • GC Phase
  • GC Length (m)
  • GC Internal Diameter (mm)
  • GC Film Thickness (µm)
  • GC Format
  • GC Option

1.00 E£ 1.00 E£ 1.0 EGP

1.00 E£

This combination does not exist.

Add to Cart Request a quote Download Datasheet (PDF)

Complete Resolution of EU 15+1 and EPA 610 PAHs


Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Zebron ZB-PAH-EU GC Columns

Priority PAH Analysis by GC

Zebron ZB-PAH-EU columns are designed to move conventional PAH testing to the exceptional, Zebron GC columns come to life through a coupling of innovation spirit and technical excellence. The Zebron ZB-PAH-EU and ZB-PAH-CT offers unparalleled performance through the power of targeted selectivity when analyzing polycyclic aromatic hydrocarbons (PAHS).

Zebron ZB-PAH-EU features
• Up to 70 % Faster PAH Analysis
• Elevated Temperature Stability (340/360 °C)
• Great Resolution of Critical Isomers, e.g. Benzo[b,j,k]fluoranthene

Recommended Use
Separation and Analysis of PAHs from Environmental, Food and Consumer Product Samples. Analysis of 15+1 EU-regulated and EPA regulated PAHs in food testing, rubber, plastic, coal, Sources include cigarette smoke, vehicle exhausts, asphalt roads, coal, coal tar, wildfires, agricultural burning, residential wood burning, municipal, industrial waste incineration.




Zebron ZB-PAH-EU GC Columns – Phenomenex

Overview


Upgrade to Zebron from traditional phases used for PAHs

Agilent®

Restek®

DB®-EUPAH

RXI®-PAH

Complete Resolution of EU 15+1 and EPA 610 PAHs

Zebron ZB-EU-PAH GC column demonstrates excellent resolution and accurate quantitation of European regulated EU 15+1 and EPA 610 PAHs.

Analysis of EU 15+1 PAHs

Zebron

Sample:

1. Benzo[c]fluorene
2. Benz[a]anthracene
3. Cyclopenta[c,d]pyrene
4. Chrysene
5. 5-Methylchrysene
6. Benzo[b]fluoranthene
7. Benzo[k]fluoranthene
8. Benzo[j]fluoranthene
9. Benzo[a]pyrene
10. Indeno[1,2,3-cd]pyrene
11. Dibenz[a,h]anthracene
12. Benzo[g,h,I]perylene
13. Dibenzo[a,l]pyrene
14. Dibenzo[a,e]pyrene
15. Dibenzo[a,i]pyrene
16. Dibenzo[a,h]pyrene

Analysis of EU 15+1 and EPA 610 PAHs


Zebron

GC-MS conditions for both applications:

Column:

Zebron ZB-PAH-EU

Dimension:

30 meter x 0.25 mm x 0.20 µm

Detector:

MSD, 50-500 m/z

Transfer line Temperature:

300 °C

Source Temperature:

300 °C

Part No.:

7CB-G043-59

Injection:

Split 15:1 @ 320 °C, 1 μL

Recommended Liner:

Zebron PLUS Single Taper Z-Liner

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 0.88 mL/min (constant flow)

Oven Program:

70 °C for 0.4 min to 180 °C @ 140 °C/min to 230 °C @ 14 °C/min for 3 min to 280 °C@ 85 °C/min for 5 min to 330 °C @ 40 °C/min for 5 min

Sample:

1. Naphthalene
2. Acenaphthylene
3. Acenaphthene
4. Fluorene
5. Phenanthrene
6. Anthracene
7. Fluoranthene
8. Pyrene

8. Pyrene
9. Benzo[c]fluorene
10. Benz[a]anthracene
11. Cyclopenta[c,d]pyrene
12. Chrysene
13. 5-Methylchrysene
14. Benzo[b]fluoranthene
15. Benzo[k]fluoranthene
16. Benzo[j]fluoranthene

17. Benzo[a]pyrene
18. Indeno[1,2,3-cd]pyrene
19. Dibenz[a,h]anthracene
20. Benzo[g,h,I]perylene
21. Dibenzo[a,l]pyrene
22. Dibenzo[a,e]pyrene
23. Dibenzo[a,I]pyrene
24. Dibenzo[a,h]pyrene

Up to 70 % Faster GC Analysis


Zebron ZB-PAH-EU will allow you to gain back your precious analysis time! You can easily optimize your column dimensions for greater speed and lab productivity.

Fast Analysis of EU 15+1 and EPA 610 PAHs using Zebron ZB-PAH-EU


Zebron

Columns:

Zebron ZB-PAH-EU

Dimension:

30 meter x 0.25 mm x 0.20 µm

Transfer Line Temperature:

300 °C

Source Temperature:

300 °C

Detector:

MSD, 50-500 m/z

Part No.:

7HG-G043-10

Injection :

Split 5:1 @ 330 °C, 1 μL

Recommended Liner:

Zebron PLUS Single Taper Z-Liner™

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 24 psi (constant pressure)

Oven Program:

45 °C for 0.8 min to 200 °C @ 45 °C/min to 226 °C @ 3 °C/min for 0 min to 320 °C @10 °C/min for 20 min

Zebron

Columns:

Zebron ZB-PAH-EU

Dimension:

20 meter x 0.18 mm x 0.14 µm

Detector:

MSD, 100-500 m/z

Source Temperature:

300 °C

Transfer Line Temperature:

300 °C

Part No.:

7FD-G043-47

Injection:

Split 5:1 @ 330 °C, 1 μL

Recommended Liner:

Zebron PLUS Single Taper Z-Liner

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 1.75 mL/min (constant flow)

Oven Program:

70 °C for 0.8 min to 180 °C @ 70 °C/min to 230 °C @ 7 °C/min for 6 min to 280 °C @ 40 °C/min for 5 min to 335 °C @ 25 °C/min for 5 min

Zebron

Columns:

Zebron ZB-PAH-EU

Dimension:

10 meter x 0.10 mm x 0.08 µm

Injection:

Split 15:1 @ 320 °C, 1 μL

Detector:

MSD, 100-500 m/z

Transfer Line Temperature:

300 °C

Source Temperature:

300 °C

Part No.:

7CB-G043-59

Recommended Liner:

Zebron PLUS Single Taper Z-Liner

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 0.88 mL/min (constant flow)

Oven Program:

70 °C for 0.4 min to 180 °C @ 140 °C/min to 230 °C @ 14 °C/min for 3 min to 280 °C @ 85 °C/min for 5 min to 330 °C @ 40 °C/min for 5 min

Sample for all applications:


1. Naphthalene
2. Acenaphthylene
3. Acenaphthene
4. Fluorene
5. Phenanthrene
6. Anthracene
7. Fluoranthene
8. Pyrene

9. Benzo[c]fluorene
10. Benz[a]anthracene
11. Cyclopenta[c,d]pyrene
12. Chrysene
13. 5-Methylchrysene
14. Benzo[b]fluoranthene
15. Benzo[k]fluoranthene
16. Benzo[j]fluoranthene

17. Benzo[a]pyrene
18. Indeno[1,2,3-cd]pyrene
19. Dibenz[a,h]anthracene
20. Benzo[g,h,I]perylene
21. Dibenzo[a,l]pyrene
22. Dibenzo[a,e]pyrene
23.Dibenzo[a,I]pyrene
24. Dibenzo[a,h]pyrene

GC-MS Analysis of PAHs in Rubber and Plastic!


Zebron ZB-PAH-EU GC column separates the 18 PAH isomers within 12 minutes, resolving all critical pairs while demonstrating consistent column inertness.

Zebron

Columns:

Zebron ZB-PAH-EU

Dimension:

10 meter x 0.10 mm x 0.08 µm

Detector:

MSD, 50-500 m/z

Transfer line Temperature:

300 °C

Source Temperature:

300 °C

Part No.:

7CB-G043-59

Injection:

Split 5:1 @ 320 °C, 1 μL

Recommended Liner:

Zebron PLUS Single Taper Z-Liner

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 0.68 mL/min (constant flow)

Oven Program:

100 °C for 3.0 min to 200 °C @ 60 °C/min to 270 °C @ 22 °C/min to 300 °C @ 4.5 °C/min to 330 °C @ 80 °C/min for 0.5 min

Sample:

1. Naphthalene
2. Acenaphthylene
3. Acenaphthene
4. Fluorene
5. Phenanthrene
6. Anthracene

7. Fluoranthene
8. Pyrene
9. Benz[a]anthracene
10. Chrysene
11. Benzo[b]fluoranthene
12. Benzo[k]fluoranthene

13. Benzo[j]fluoranthene
14. Benzo[a]pyrene
15. Benzo[e]pyrene
16. Indeno[1,2,3-cd]pyrene
17. Dibenz[a,h]anthracene
18. Benzo[g,h,i]perylene

Fast and Accurate GC-MS Test Method for Measuring PAHs in Food


Zebron ZB-PAH-EU is an excellent solution for separating the four most common PAH markers within the European Food Safety Authority EFSA PAH4 for food analysis.

Super Fast Analysis of Food PAHs Using ZB-PAH-EU

Zebron

Columns:

Zebron ZB-PAH-EU

Dimension:

10 meter x 0.10 mm x 0.08 µm

Detector:

MSD, 100-500 m/z

Transfer Line Temperature:

300 °C

Source Temperature:

300 °C

Part No.:

7CB-G043-59

Injection:

Split 15:1 @ 320 °C, 1 μL

Recommended Liner:

Zebron PLUS Single Taper Z-Liner

Liner Part No.:

AG2-4B13-05 (for Shimadzu® 2010 GC)

Carrier Gas:

Helium @ 0.88 mL/min (constant flow)

Oven Program:

70 °C for 0.4 min to 180 °C @ 140 °C/min to 230 °C @ 14 °C/min for 3 min to 280 °C@ 85 °C/min for 5 min to 330 °C @ 40 °C/min for 5 min

Sample:

10 ppm EFSA PAH4 Standard in Toluene
1. Benz[a]anthracene
2. Chrysene
3. Benzo[b]fluoranthene
4. Benzo[a]pyrene

Sample:

10 ppm EFSA PAH4 Standard in Toluene
1. Benz[a]anthracene
2. Chrysene
3. Benzo[b]fluoranthene
4. Benzo[a]pyrene

Documents

FAQs

Can I pack or re-pack my GC liner with wool?

Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.

Does the Zebron PLUS liner with wool improve my GC column lifetime?

Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.

I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?

It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.

Is there a way I can get immediate help with my current and upcoming method?

Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.

I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?

For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.

When facing peak and resolution issues in sample analysis by GC, where is the best place to start?

The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.

Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?

Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.

Manufacturer information: Zebron ZB-PAH-EU GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.

Specifications for Zebron ZB-PAH-EU GC Columns

GC Length (m) 10 or 20 or 30 or 60
GC Internal Diameter (mm) 0.1 or 0.18 or 0.25
GC Film Thickness (µm) 0.08 or 0.14 or 0.2
GC Option Standard or w/ GUARDIAN 5 m
Manufacturer Phenomenex
GC Phase ZB-PAH-EU
GC Format Capillary Column