Synergi LC Columns

  • Manufacturer
  • Column Phase
  • Column Particle Size
  • Column Length
  • Column Internal Diameter
  • Column Pore Size
  • Column Format
  • Column Option

1.00 E£ 1.00 E£ 1.0 EGP

1.00 E£

This combination does not exist.

Add to Cart Request a quote Download Datasheet (PDF)

Full Range of Selectivity for Reversed Phase Separation


Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Synergi HPLC Columns

Full Range of Selectivity for Reversed Phase Separation

Many different mechanisms of retention are utilized within reversed-phase chromatography in order to retain and separate target analytes. Whether your compounds are hydrophobic or polar, Synergi columns provide you with a full range of selectivity, ensuring the separation of the most challenging and complex mixtures.

Synergi HPLC Columns – Phenomenex
Separation techniqueReversed Phase (RP)
ApplicationSmall Molecule Analysis
Pore size80 Å, 100 Å
Particle size2.5 µm, 4 µm, 10 µm
Phases available4
Catalogue codes167

Full Range Selectivity

Synergi HPLC Columns four unique phases developed to provide a different selectivity for successful separations of the most complex mixtures and challenging analytes under reversed phase conditions.

Synergi
Synergi Fusion-RP

C18 Polar Embedded

Balanced non-polar and polar performances

Synergi
Synergi Hydro-RP

C18 Polar Embedded

Strong non-polar and polar retention

Synergi
Synergi Max-RP

C12 TMS Endcapped

Excellent for basic compounds at neutral pH

Synergi
Synergi Polar-RP

Phenyl Ether-Linked

For polar and aromatic mixtures

Phases

Reversed Phase

Synergi Fusion-RP

Polar embedded C18 with TMS endcapping

Synergi Fusion-RP phase

Recommended Use: Separation of mixtures with both polar and non-polar compounds

Particle Size: 10 µm, 4 µm, 2.5 µm

Reversed Phase

Synergi Hydro-RP

C18 with polar endcapping

Synergi Hydro-RP phase

Recommended Use: Separation of weakly hydrophobic compounds; 100% aqueous stable

Particle Size: 10 µm, 4 µm, 2.5 µm

Reversed Phase

Synergi Max-RP

C12 with TMS endcapping

Synergi Max-RP phase

Recommended Use: Separation of basic compounds under neutral pH

Particle Size: 10 µm, 4 µm, 2.5 µm

No Separation Mode

Synergi No Phase

Recommended Use: —

Particle Size: 10 µm, 4 µm, 2.5 µm

Reversed Phase

Synergi Polar-RP

Ether-linked phenyl with polar endcapping

Synergi Polar-RP phase

Recommended Use: Separation of polar, aromatic compounds

Particle Size: 10 µm, 4 µm, 2.5 µm

Documents

FAQs

What is chromatography?

Chromatography is the separation of components in a mixture based on their chemical nature. Chromatography can be performed in either liquid (HPLC) or gas (GC) forms. Liquid chromatography, specifically High Pressure Liquid Chromatography (HPLC), involves a stationary phase (sorbent), a mobile phase (liquid) and the analyte or compounds of interest. Analytes or compounds of interest are injected onto an HPLC column (packed with sorbent that contains a variety of chemistries) in mobile phase. As the mobile phase, which is carrying the analyte or compounds of interest, travels across the stationary phase, the analyte or compounds of interest separate from each other as they interact with the stationary phase, each eluting from the column at various times. Gas chromatography (GC) is similar to HPLC in that is utilized with working analytes or compounds of interest that can be vaporized without decomposing. In GC, gas is used instead of a liquid (like in HPLC). As analytes or compounds of interest travel in the gas mobile phase and interact with the stationary phase, eluting at various times.

Does high pH mobile phase reduce the sensitivity of basic analytes in LC-MS?

Using high pH mobile phase, the retention of polar bases will be increased. Signal response does depend upon ionization state, so if we use high pH, we are actually de-ionizing our bases and should lose sensitivity. But this doesn’t happen actually. When we increase the retention of the polar base analytes using high pH, it elutes later in the gradient run and in a high percentage of organic (acetonitrile or methanol). For example, when using formic acid, the polar base analyte peak is eluting in about 5-10% acetonitrile, but when we switch to pH 10, the polar base analyte peak is coming off in about 30-40% acetonitrile. The increased % of acetonitrile in the source is what allows the ions to be ionized thoroughly, thereby giving you a better response in ESI-MS.

What changes are allowed to USP / EP gradient HPLC methods?

When using a gradient method, no change may be made to particle size or column dimensions. They must be the same as those directed in the monograph.

I am looking to switch my pesticide methods from GC-MS to LC-MS, what do you recommend?

In general, a column with polar selectivity, such as Synergi Fusion-RP or Kinetex Biphenyl, will preform well for pesticide/herbicide screens using LC/MS/MS.

Manufacturer information: Synergi HPLC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.

Specifications for Synergi LC Columns

Column Phase MAX-RP or Max-RP or Hydro-RP or Polar-RP or Fusion-RP
Column Particle Size 2.5 or 4 or 10
Column Length 10 or 20 or 30 or 50 or 75 or 100 or 125 or 150 or 250 or 300 or N/A
Column Internal Diameter 0.3 or 0.5 or 1 or 2 or 3 or 3.9 or 4 or 4.6 or 10 or 21.2 or 30 or 50 or N/A
Column Pore Size 80 or 100
Column Format MercuryMS or Bulk Media or Analytical or Capillary / Nano or Preparative (AXIA Packed)
Column Option Standard or AXIA Packed or Capillary or MercuryMS or Titanium Frits
Manufacturer Phenomenex