Zebron ZB-1HT GC Columns
Robust Results Up to 430 ºC
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron ZB-1HT Inferno GC Columns
Robust Results Up to 430 ºC
- First non-metal columns stable to 430 °C
- Provides true boiling point separation for hydrocarbon distillation methods
- Longer lifetime with rugged high temperature, polyimide coated, fused silica tubing
- Low activity, provides good peak shape for acidic and basic samples
- Provides robust column performance for high temperature bake outs
Recommended Use
Diesel Fuel, High Boiling Petroleum Products, High Molecular Weight Waxes, Long-chained Hydrocarbons, Motor Oils, Polymers/Plastics, Simulated Distillation
Overview
Upgrade to Zebron from any 100 % dimethylpolysiloxane phase
Agilent® | Restek® | SGE® | Supelco® |
|---|---|---|---|
| DB®-1 | Rtx®-1 | BP1 | SPB®-1 |
| DB-1htHP-1 | Petrocol® 2887 | ||
| CP-Sil 5 CB | |||
| CP-SimDist |
Rugged, High-Temperature Performance
Great Separation of High Boiling Hydrocarbons (ASTM D6352)
Column: | Zebron ZB-1HT Inferno |
Dimension: | 5 meter x 0.53 mm x 0.10 μm |
Part No. | |
Injection: | On-Column @ 43 °C, 0.1 μL |
Carrier Gas: | Helium @ 4.4 mL/min (constant flow) |
Oven Program: | 40 °C for 0.5 min to 430 °C @ 20 °C/min for 10 min |
Detection: | FID @ 430 °C |
Sample:
1. C10
2. C11
3. C12
4. C13
5. C14
6. C15
7. C16
8. C17
9. Pristane
10. C18
11. Phytane
12. C19
13. C20
14. C21
15. C22
16. C23
17. C24
18. C25
19. C26
20. C27
31. C38
32. C39
33. C40
34. C42
35. C44
36. C46
37. C48
38. C50
39. C52
40. C54
41. C56
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
41. C56
42. C58
43. C60
44. C62
45. C64
46. C66
47. C68
48. C70
49. C72
50. C74
51. C76
52. C78
53. C80
54. C82
55. C84
56. C86
57. C88
58. C90
Bake Off Contaminants from Dirty Matrices
Column: | Zebron ZB-1HT Inferno |
Dimension: | 30 meter x 0.25 mm x 0.10 µm |
Part No. | |
Injection: | On-Column @ 153 °C, 1 µL |
Carrier Gas: | Helium @ 1 mL/min (constant flow) |
Oven Program: | 150 °C to 400 °C @ 14 °C/min for 6 min |
Detection: | FID @ 400 °C |
Sample:
Sample was 1 % in dichloromethane Mobil® 1 10W-30 Fully Synthetic Motor Oil
Run Versatile Samples
Hydrocarbons from Water by GC-FID DIN EN ISO 9377-2 (DEV H53)
Column: | Zebron ZB-1HT Inferno |
Dimension: | 15 meter x 0.32 mm x 0.25 μm |
Part No. | |
Injection: | Splitless @ 300 °C, 20 μL |
Carrier Gas: | Helium @ 2.0 mL/min (constant flow) |
Oven Program: | 50 °C for 2 min to 320 °C @ 30 °C/min for 5 min |
Detection: | FID @ 330 °C |
Sample:
1. Decane (C10)
2. Tetracontane (C40)
Documents
- Technical Notes: Orthogonal Selectivity for Separation of Light and Heavy Petroleum Hydrocarbons by 2D GC using Zebron ZB-1HT Inferno and ZB-35HT Inferno GC Columns (TN-2085)
- Guide: GC Troubleshooting Quick Reference Guide
- Guide: Zebron GC Column Selection Chart
- Brochures: Zebron Gas Management Brochure
- Supporting Docs: Zebron Gas Filter Selection Tool
- Supporting Docs: Zebron Gas Filter User Guide
- Technical Notes: Group-Type Analysis of Petroleum Products by GC×GC using Zebron ZB-1HT Inferno and ZB-50 Complementary Selectivity GC Columns (TN-2086)
- Brochures: Chemical Industry LC & GC Separation Solutions Guide
FAQs
Can I pack or re-pack my GC liner with wool?
Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.
Does the Zebron PLUS liner with wool improve my GC column lifetime?
Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.
I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?
It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.
Is there a way I can get immediate help with my current and upcoming method?
Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.
I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?
For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.
When facing peak and resolution issues in sample analysis by GC, where is the best place to start?
The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.
Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?
Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.
Manufacturer information: Zebron ZB-1HT Inferno GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
Specifications for Zebron ZB-1HT GC Columns
| GC Length (m) | 5 or 10 or 15 or 20 or 30 or 60 or N/A |
| GC Internal Diameter (mm) | 0.18 or 0.25 or 0.32 or 0.53 or N/A |
| GC Film Thickness (µm) | 0.1 or 0.15 or 0.18 or 0.25 or 0.88 or N/A |
| GC Format | Capillary Column or 5-inch Cage |
| GC Option | Standard or Custom or w/ GUARDIAN 5 m, Custom or w/ GUARDIAN 5 m or Reverse Winding |
| Manufacturer | Phenomenex |
| GC Phase | ZB-1HT |