Zebron ZB-FAME GC Columns

  • Manufacturer
  • GC Phase
  • GC Length (m)
  • GC Internal Diameter (mm)
  • GC Film Thickness (µm)
  • GC Format
  • GC Option

1.00 E£ 1.00 E£ 1.0 EGP

1.00 E£

This combination does not exist.

Add to Cart Request a quote Download Datasheet (PDF)

Accelerating FAME Testing


Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Zebron ZB-FAME GC Columns

The Fast FAME GC Column

  • Reduce run times for traditional FAMEs separations up to 75 %
  • Separate cis/trans FAME isomers with Rs ≥ 1.0
  • High-cyanopropyl selectivity acceptable for use with AOCS, AOAC, and IOC methods

Application Notes:

  • Reproducible FAME Analysis on a 100 meter Zebron™ ZB-FAME GC Column. Read more.
  • Demonstration of Robustness and Selectivity for the Analysis of FAMEs in Salmon Oil and Pet Food. Read more.

Recommended Use
Fatty acid methyl esters (FAMEs), cis/trans FAME isomers, Omega 3 and Omega 6 FAMES




Zebron ZB-FAME GC Columns – Phenomenex

Overview


Upgrade to Zebron from any high cyanopropyl phase:

Agilent®

Supelco®

CP-Sil 88

SP®-2380

HP-88SP-2560

DB®-23

Accelerating FAME Testing

Designed to move beyond the conventional to the exceptional , Zebron GC columns come to life through a coupling of innovative spirit and technical excellence. As part of the Zebron Unlimited series of columns, Zebron ZB FAME offers unparalleled performance through the power of targeted selectivity when analyzing fatty acid methyl esters (FAMEs)
Optimized High-Cyano Polarity
FAME separations require the use of high polarity columns for adequate resolution of cis/trans isomers. Zebron™ ZB-FAME is an optimized high-cyanopropyl (G48) chemistry that provides the polarity that you need, while remaining compatible with AOAC, OCS, and IOC regulatory methods.

Elution Order for 37 FAME Standard


Peak

Compound

ID

1Butanoic Acid Methyl EsterC4:0
2Hexanoic Acid Methyl Ester2C6:0
3Octanoic Acid Methyl EsterC8:0
4Decanoic Acid Methyl EsterC10:0
5Undecanoic Acid Methyl EsterC11:0
6Dodecanoic Acid Methyl EsterC12:0
7Tridecanoic Acid Methyl EsterC13:0
8Myristic Acid Methyl EsterC14:0
9Myristoleic Acid Methyl EsterC14:1 cis 9
10Pentadecanoic Acid Methyl EsterC15:0
11cis-10-Pentadecenoic Acid Methyl EsterC15:1 cis 10
12Hexadecanoic Acid Methyl EsterC16:0
13Palmitoleic Acid Methyl EsterC16:1 cis 9
14Heptadecanoic Acid Methyl EsterC17:0
15cis-10-Heptadecenoic Acid Methyl EsterC17:1 cis 10
16Stearic Acid Methyl EsterC18:0
17Elaidic Acid Methyl EsterC18:1 trans 9
18Oleic Acid Methyl EsterC18:1 cis 9
19Linolelaidic Acid Methyl EsterC18:2 trans 9,12

Peak

Compound

ID

1Linoleic Acid Methyl EsterC18:2 cis 9,12
2γ-Linolenic Acid Methyl EsterC18:3 cis 6,9,12
3α-Linolenic Acid Methyl EsterC18:3 cis 9,12,15
4Arachidic Acid Methyl EsterC20:0
5cis-11-Eicosenoic Acid Methyl EsterC20:1 cis 11
6cis-11,14-Eicosadienoic Acid Methyl EsterC20:2 cis 11,14
7Heneicosanoic Acid Methyl EsterC21:0
8cis-8,11,14-Eicosatrienoic Acid Methyl EsterC20:3 cis 8,11,14
9Arachidonic Acid Methyl EsterC20:4 cis 5,8,11,14
10cis-11,14,17-Eicosatrienoic Acid Methyl EsterC20:3 cis 11,14,17
11Behenic Acid Methyl EsterC22:0
12Erucic Acid Methyl EsterC22:1 cis 13
13cis-5,8,11,14,17-Eicosapentaenoic Acid Methyl EsterC20:5 cis 5,8,11,14,17
14cis-13,16-Docosadienoic Acid Methyl EsterC22:2 cis 13,16
15Tricosanoic Acid Methyl EsterC23:0
16Lignoceric Acid Methyl EsterC24:0
17Nervonic Acid Methyl EsterC24:1 cis 15
18cis-4,7,10,13,16,19-Docosahexaenoic Acid Methyl EsterC22:6 cis 4,7,10,13,16,19

QC Tested For FAMEs

Zebron

Baseline Separation of Common Isomers


Food and dietary standards require separation of cis/trans fatty acids. Zebron™ ZB-FAME is able to separate from C4 to C24 with resolution of specific cis/trans fatty acids.

Completely Resolve AOAC Critical Pairs


Zebron

Columns:

Zebron ZB-FAME

Dimension:

30 meter x 0.25 mm x 0.20 µm

Detector:

FID @ 260 °C

Part No.:

7HG-G033-10

Injection:

Split 50:1 @ 240 °C, 1 µL

Recommended Liner:

Zebron PLUS Single Taper with Wool

Liner Part No.:

AG2-0A11-05 (for Agilent® systems)

Carrier Gas:

Helium @ 1.2 mL/min (constant flow)

Oven Program:

100 °C for 2 min to 140 °C @ 10 °C/minto 190 °C @ 3 °C/min to 260 °C @ 30 °C/min for 2 min

Sample:

37 FAME standard

Separate Detailed C18 Compounds


Due to regulatory guidelines around trans fat content in food, detailed analysis of specific FAMEs isomers is commonly performed. The below methods demonstrate this testing using a 60 meter Zebron™ ZB-FAME column.

Analysis of C18:1, C18:2, and C18:3


Zebron

Columns:

Zebron ZB-FAME

Dimension:

60 meter x 0.25 mm x 0.20 µm

Detector:

FID @ 260 °C

Part No.:

7KG-G033-10

Injection:

Split 50:1 @ 240 °C, 1 µL

Recommended Liner:

Zebron PLUS Single Taper with Wool

Liner Part No.:

AG2-0A11-05 (for Agilent® systems)

Carrier Gas:

Helium @ 30 cm/sec (constant flow)

Oven Program:

160 °C (isothermal)

Sample:

As listed. For full peak identification, visit www.phenomenex.com/DetailedFAME

Twice The Runs, Half The Time


37 FAMEs In A Short 11 Minute Run


Traditionally, cis/trans FAME separations require the use of long (100 meters or more) columns and can run up to 60 minutes, resulting in a bottleneck to higher productivity. Zebron™ ZB-FAME provides targeted selectivity that allows for reduced column length – run times as short as 11 minutes without compromising your results!

Zebron

Columns:

Zebron ZB-FAME

Dimension:

20 meter x 0.18 mm x 0.15 μm

Detector:

FID @ 260 °C

Part No.:

7FD-G033-05

Injection:

Split 100:1 @ 250 °C, 1 µL

Recommended Linear:

Zebron PLUS Single Taper Z-Liner™

Liner Part No.:

AG2-0A13-05 (for Agilent® systems)

Carrier Gas:

Helium @ 1.0 mL/min (constant flow)

Oven Program:

80 °C for 1.5 min to 160 °C @ 40 °C/min to 185 °C @ 5 °C/min to 260 °C @ 30 °C/min

Sample:

37 FAME standard

Documents

FAQs

Can I pack or re-pack my GC liner with wool?

Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.

Does the Zebron PLUS liner with wool improve my GC column lifetime?

Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.

I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?

It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.

Is there a way I can get immediate help with my current and upcoming method?

Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.

I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?

For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.

When facing peak and resolution issues in sample analysis by GC, where is the best place to start?

The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.

Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?

Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.

Manufacturer information: Zebron ZB-FAME GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.

Specifications for Zebron ZB-FAME GC Columns

GC Length (m) 20 or 30 or 60 or 100
GC Internal Diameter (mm) 0.18 or 0.25
GC Film Thickness (µm) 0.15 or 0.2
GC Format Capillary Column or 5-inch Cage
GC Option Standard or w/ GUARDIAN 5 m
Manufacturer Phenomenex
GC Phase ZB-FAME