Zebron ZB-XLB-HT GC Columns
Extra Low Bleed with High Temperature Stability
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron ZB-XLB-HT Inferno GC Columns
High Temp Stability, Low Bleed
- Rugged, non-metal si-arylene GC column stable to 400 ˚C
- Robust column for high temperature bake outs and analysis, such as high molecular weight compounds
- Provides unique selectivity for conformational analyses
- Longer lifetime with high temperature, polyimide coated, fused silica tubing
- Low activity, provides good peak shape for acidic and basic samples
- Good tool for general screening to identify unknown samples
Recommended Use
Herbicides/Insecticides, PCBs, Pesticides, Unknown Samples
Overview
Upgrade to Zebron from these similar* phases:
Aroclor 1242: DIN Method 51527
Column: | Zebron ZB-XLB-HT Inferno |
Dimension: | 30 meter x 0.25 mm x 0.25 µm |
Detection: | ECD @ 350 °C |
Part No.: | 7HG-G024-11 |
Injection: | Split 2:1 @ 250 °C, 1 µL, pressure pulse @ 40 psi for first 0.25 min |
Carrier: | Helium @ 1.5 mL/min (constant flow) |
Oven Program: | 50 °C for 0.5 min to 210 °C @ 40 °C/min for 3 min to 230 °C @ 30 °C/min for 5 min to 250 °C @ 30 °C/min for 5 min to 320 °C@ 40 °C/min for 2 min |
Sample:
Total concentration of aroclors was 90 ppm in isooctane.
1. TCMX
2. BZ# 31
3. BZ# 28
4. BZ# 52
5. BZ# 101
6. BZ# 77
7. BZ# 123
8. BZ# 118
9. BZ# 153
10. BZ# 114
11. BZ# 105
12. BZ# 138
13. BZ# 126
14. BZ# 167
15. BZ# 156
16. BZ# 180
17. BZ# 157
18. BZ# 170
19. BZ# 169
20. BZ# 189
21. DCB
Melamine and Cyanuric Acid by GC-MS
Columns: | Zebron ZB-XLB-HT Inferno |
Dimension: | 15 meter x 0.25 mm x 0.25 µm |
Detector: | MSD @ 325 °C |
Part No.: | 7EG-G024-11 |
Injection: | On-Column @ 103 °C, 1 µL |
Carrier Gas: | Helium @ 1.4 mL/min (constant flow) |
Oven Program: | 100 °C for 0.5 min to 320 °C @ 25 °C/min |
Sample:
Analytes are 200 ng / 100 µL in BSTFA / Pyridine (1:1)
1. Cyanuric Acid 13C3 (IS)
2. Cyanuric Acid
3. Melamine 13C3 15N3 (IS)
4. Melamine
Good Results for Difficult Samples
Explosives by GC-MS
Columns: | Zebron ZB-XLB-HT Inferno |
Dimension: | 15 meter x 0.25 mm x 0.25 µm |
Detector: | MSD @ 325 °C |
Part No.: | 7EG-G024-11 |
Injection: | On-Column @ 73 °C, 0.5 µL |
Carrier Gas: | Helium @ 1.4 mL/min (constant flow) |
Oven Program: | 70 °C for 1 min to 140 °C @ 25 °C/min for 4 min to 280 °C @ 25 °C/min |
Sample:
Analytes are 10 ppm in dichloromethane
1. Nitrobenzene
2. 2-Nitrotoluene
3. 3-Nitrotoluene
4. 4-Nitrotoluene
5. Nitroglycerin
6. 2,6-Dinitrotoluene (2,6-DNT)
7. 1,3-Dinitrobenzene (1,3-DNB)
8. 2,4-Dinitrotoluene
9. 2,4,6-Trinitrotoluene (2,4,6-TNT)
10. PETN
11. 1,3,5-Trinitrobenzene (1,3,5-TNB
12. RDX
13. 4-Amino-2,6-dinitrotoluene
14. 3,5-Nitroaniline
15. 2-Amino-4,6-dinitrotoluene
16. Tetryl
Documents
- Guide: GC Troubleshooting Quick Reference Guide
- Guide: Zebron GC Column Selection Chart
- Brochures: Zebron Gas Management Brochure
- Supporting Docs: Zebron Gas Filter Selection Tool
- Supporting Docs: Zebron Gas Filter User Guide
- Brochures: Zebron Inferno GC Columns
FAQs
Can I pack or re-pack my GC liner with wool?
Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.
Does the Zebron PLUS liner with wool improve my GC column lifetime?
Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.
I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?
It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.
Is there a way I can get immediate help with my current and upcoming method?
Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.
I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?
For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.
When facing peak and resolution issues in sample analysis by GC, where is the best place to start?
The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.
Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?
Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.
Manufacturer information: Zebron ZB-XLB-HT Inferno GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
Specifications for Zebron ZB-XLB-HT GC Columns
| GC Length (m) | 15 or 20 or 30 or 60 |
| GC Internal Diameter (mm) | 0.18 or 0.25 or 0.32 |
| GC Film Thickness (µm) | 0.1 or 0.18 or 0.25 |
| GC Format | Capillary Column or 5-inch Cage |
| Manufacturer | Phenomenex |
| GC Phase | ZB-XLB-HT |
| GC Option | Standard |