Zebron ZB-624 GC Columns
Robust Results for VOCs and Residual Solvents
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron ZB-624 GC Columns
Robust Results for VOCs and Residual Solvents
- Widely used phase to separate volatile organic flavor and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs)
- Popular choice for residual solvent testing
- Excellent for US EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 624, 8010, 8015, 8020, 8021, 8240, 8260
- Specifically designed for the separation of volatile organic compounds (VOCs)
- Increased temperature limit speeds run times and re-equilibration
Need a G16 phase for residual solvents? See ZB-WAX
Recommended Use
EPA Methods (501.3, 502.2, 503.1, 524.2, 601, 602, 624, 8010, 8015, 8020, 8021, 8240, 8260), Pharmaceuticals, Residual Solvents, Volatile Organic Compounds (VOCs)
Overview
Upgrade to Zebron from any 6 % cyanopropylphenyl / 94 % dimethylpolysiloxane phase:
Agilent® | Restek® | SGE® | Supelco® | OV® |
|---|---|---|---|---|
DB®-624 | Rtx®-624 | BPX624 | SPB®-624 | OV-624 |
| DB-1301 | Rtx-1301 | SPB-1301 | ||
| DB-VRX | Rtx-VMS | |||
| HP-VOC | ||||
| CP-1301 | ||||
| CP-Select 624 CB |
Zebron GC Column Benefits
Good Performance for Pharmaceuticals
USP <467> Residual Solvents Procedure A — Class 1
Column: | Zebron ZB-624 |
Dimension: | 30 meter x 0.32 mm x 1.80 µm |
Detector: | FID @ 250 °C |
Part No.: | 7HM-G005-31 |
Injection: | Split 5:1 @ 140 °C, 1 mL |
Carrier Gas: | Helium @ 35 cm/sec (constant flow) |
Oven Program: | 40 ˚C for 20 min to 240 ˚C @ 10 ˚C/min for 20 min |
Sample:
1. 1,1-Dichloroethene
2. 1,1,1-Trichloroethane
3. Carbon tetrachloride
4. Benzene
5. 1,2-Dichloroethane
EPA Method 8260: Volatile Organic Analysis
Column: | Zebron ZB-624 |
Dimension: | 20 meter x 0.18 mm x 1.00 µm |
Detector: | MSD; 35-275 amu |
Part No.: | 7FD-G005-22 |
Injection: | Purge and Trap |
Carrier Gas: | Helium (constant flow) |
Oven Program: | 35 ˚C to 210 ˚C |
Sample:
1. Chloromethane
2. Vinyl chloride
3. Bromomethane
4. Chloroethane
5. Trichlorofluoromethane
6. Ethanol
7. Dichlorotrifluoroethane
8. Acrolein
9. Trichlorotrifluoroethane
10. 1, 1-Dichloroethene
11. Acetone
12. Methyl iodide
13. Carbon disulfide
14. Methylene chloride
15. t-Butanol
16. trans-1,2-Dichloroethane
17. Methyl-t-butyl ether
18. Acrylonitrile
19. 1, 1-Dichloroethane
20. Vinyl Acetate
21. Diisopropyl ether
22. Ethyl-t-butyl ether
23. 2, 2-Dichloropropane
24. cis-1, 2-Dichloroethene
25. 2-Butanone
26. Bromochloromethane
27. Chloroform
28. Tetrahydrofuran
29. 1, 1, 1-Trichloroethane
30. 1, 1-Dichloropropene
31. Carbon tetrachloride
32. 1, 2-Dichloroethane-d4
33. Benzene
34. 1, 2-Dichloroethane
35. t-Amyl methyl ether
36. Fluorobenzene
37. Trichloroethene
38. 1, 2-Dichloropropane
39. Dibromomethane
40. Bromodichloromethane
41. 2-Chloroethylvinyl ether
42. cis-1, 3-Dichloropropene
43. Methyl isobutyl ketone
44. Toluene-d8
45. Toluene
46. trans-1, 3-Dichloropropene
47. 1, 1, 2-Trichloroethane
48. Tetrachloroethene
49. 1, 3-Dichloropropane
50. 2-Hexanone
51. Dibromochloromethane
52. Ethylene dibromide
53. Chlorobenzene
54. 1, 1, 1, 2-Tetrachloroethane
55. Ethylbenzene
56. m,p-Xylene
57. o-Xylene
58. Styrene
59. Bromoform
60. Isopropylbenzene
61. 4-Bromofluorobenzene
62. 1, 1, 2, 2-Tetrachloroethane
63. Bromobenzene
64. 1, 2, 3-Trichloropropane
65. n-Propylbenzene
66. 2-Chlorotoluene
67. 1, 3, 5-Trimethylbenzene
68. 4-Chlorotoluene
69. tert-Butylbenzene
70. 1, 2, 4-Trimethylbenzene
71. sec-Butylbenzene
72. 1, 3-Dichlorobenzene
73. 4-Isopropyltoluene
74. 1, 4-Dichlorobenzene
75. n-Butylbenzene
76. 1, 2-Dichlorobenzene-d4
77. 1, 2-Dichlorobenzene
78. 1, 2-Dibromo-3-chloropropane
79. 1, 2, 4-Trichlorobenzene
80. Hexachlorobutadiene
81. Naphthalene
82. 1, 2, 3-Trichlorobenzene
Meet Zebron ZB-624PLUS!
- Enhanced Peak Shape with Superior Deactivation
- Increased Sensitivity for High Boiling Solvents
- Extremely Low Bleed for GC-MS
- High Temperature Stability (300/320 ˚C)
Documents
- Guide: GC Troubleshooting Quick Reference Guide
- Supporting Docs: Zebron Essentials Phases
- Brochures: Zebron Essentials Brochure
- Guide: Zebron GC Column Selection Chart
- Brochures: Zebron Gas Management Brochure
- Brochures: Zebron™ ZB-624PLUS Brochure
- Supporting Docs: Zebron Gas Filter User Guide
- Supporting Docs: Zebron Gas Filter Selection Tool
- Technical Notes: Solvent Purity Estimation Using a Zebron ZB-624PLUS GC Column
- Technical Notes: VOC Analysis Including 1,4-Dioxane and 1,2-Dichloropropane by GC-MS Using A Zebron ZB-624 GC Column
- Technical Notes: Environmental Contaminants Caused by the Oil Spill in the Gulf of Mexico by GC and HPLC (TN-2045)
- Technical Notes: Ph. Eur. Monograph 1317: A Means of Improving the Resolution Between Acetaldehyde and Methanol in the Limit Test for 96% Ethanol
FAQs
Can I pack or re-pack my GC liner with wool?
Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.
Does the Zebron PLUS liner with wool improve my GC column lifetime?
Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.
I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?
It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.
Is there a way I can get immediate help with my current and upcoming method?
Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.
I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?
For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.
When facing peak and resolution issues in sample analysis by GC, where is the best place to start?
The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.
Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?
Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.
Manufacturer information: Zebron ZB-624 GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
Specifications for Zebron ZB-624 GC Columns
| GC Length (m) | 20 or 25 or 30 or 60 or 75 or 90 or 105 or 135 |
| GC Internal Diameter (mm) | 0.18 or 0.2 or 0.25 or 0.32 or 0.53 |
| GC Film Thickness (µm) | 0.25 or 1 or 1.12 or 1.4 or 1.8 or 3 |
| GC Format | Capillary Column or 5-inch Cage |
| GC Option | Standard or Custom or w/ GUARDIAN 5 m |
| Manufacturer | Phenomenex |
| GC Phase | ZB-624 |