Zebron Z-Guard Metal Guard Column
Universal GC Guard Columns
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron Z-Guard™ GC Columns
Protect and Extend Column Lifetime
- Individually QC tested to ensure the highest level of quality
- Extend column lifetime by preventing stationary phase damage
- Improve separation and peak shapes (especially early elutors)
- Improve sensitivity and accuracy of quantitative results
- Available as individual guard columns or as complete kits with connectors
To ensure that all Z-Guards are the highest possible quality, we individually test each one! The columns are attached to a reference Zebron ZB-5 column and are tested using our specially designed QC mix. We carefully monitor activity, bleed, and stability. This way, we are able to say with confidence that Z-Guards will provide the low activity and high quality your methods require.
Overview
Zebron Z-Guard Phase Information
Z-Guard columns are universal GC guard columns, designed for use with virtually any GC capillary column, from virtually any manufacturer.
- Extend column lifetime by preventing stationary phase damage
- Improve separation, peak shapes (especially early elutors), sensitivity, and accuracy of quantitative results
- Alternative to Agilent, Restek, Supelco, and many more
Easy Use Z-Guard Column Kits
Try Z-Guard columns individually or get the convenient, complete kit. Each kit includes:
- 5 or 10 meters of deactivated fused-silica tubing
- 5 universal connectors
- 0.5 mL of high-temperature polyimide resin
Guard Column Usage
Tips: Using Z-Guard Columns
When using a guard at high temperatures, make sure that the press-fit connection is secure.
The most important aspect of a good seal is a good column cut.
- The column end should be square and smooth (like a straw). Any irregularities will cause leaks.
- Columns are long - repeat cutting until a good cut is achieved.
- Lightly scoring the column usually creates a cleaner opening.
Documents
- Guide: GC Troubleshooting Quick Reference Guide
- Guide: Zebron GC Column Selection Chart
- Brochures: Zebron Gas Management Brochure
- Supporting Docs: Zebron Gas Filter Selection Tool
- Supporting Docs: Zebron Gas Filter User Guide
- Guide: Persistent Organic Pollutants (POPs) by GC
- Supporting Docs: Zebron Essentials Phases
FAQs
Can I pack or re-pack my GC liner with wool?
Though the upfront cost of self-packing your liner may seem attractive, the time and headaches caused by resulting tailing or irreproducible peaks can be sizeable! Self-packed wool fibers commonly break during installation and any existing deactivation on the liner can also be scratched or damaged. Scratches in the deactivation layer are likely to occur when removing wool from the liner or re-packing it with new wool. Also, when wool is forcefully inserted or removed, these scratches could expose active sites, resulting in peak tailing and poor reproducibility. Pre-packed Zebron PLUS liners undergo the deactivation process with the quartz wool already in place, which ensures that any active sites that form during packing are not exposed. Its novel touchless packaging and preinstalled O-ring prevent contamination during installation.
Does the Zebron PLUS liner with wool improve my GC column lifetime?
Yes. Zebron PLUS liners are packed with quartz wool, which serves two purposes: a) Quartz wool promotes homogenous vaporization of analytes and solvent in the inlet to effectively transfer them to the head of the GC column. b) Quartz wool acts as a filter, trapping non-volatile impurities and preventing them from proceeding further into the GC column.
I work with dirty samples which produce a residue on my GC liner after approximately 100 injections. Can I scrub/sonicate my liner and reuse it?
It is not recommended to scrub/sonicate your liners. Residue formation indicates contamination. More specifically, this shows that the sample contains non-volatile impurities, in which case it is recommended to replace your liner rather than clean it. Sonication can alter the liner’s deactivation, and scrubbing can create scratches and active sites. As a result, you can have several chromatography problems such as poor quantitation, analyte breakdown, poor reproducibility, peak asymmetry, etc.
Is there a way I can get immediate help with my current and upcoming method?
Absolutely, we're always here to help! You can easily get in contact with our team members by clicking contact us on the menu or better yet, just head to www.phenomenex.com/chatnow and we'll help you out with method recommendations and tips.
I am using an inert GC column for my analysis, and I still see peak tailing. What could be the reason for this?
For analysis of active compounds, it is crucial to use both a highly inert column and a highly inert liner. The liner is the first place of potential analyte interaction during GC analysis; it is important that your analytes are not adsorbed. Zebron PLUS liners undergo a rigorous deactivation process and are tested for inertness to ensure reliable results when working with highly active compounds such as underivatized acids and active bases.
When facing peak and resolution issues in sample analysis by GC, where is the best place to start?
The inlet is the most common place where problems happen in gas chromatography. This is because: • The inlet is subjected to very high temperatures. • There are multiple consumables involved in the inlet that need routine maintenance. • Some inlet modes, such as splitless injection, are a slow process, meaning that target analytes and the inlet can interact with each other before the sample enters the column.
Can you recommend a GC liner that work best when analyzing dirty samples, samples with wide boiling points, or samples with wide molecular weight?
Analysis of dirty samples, samples with wide boiling points, or samples with wide molecular weights can be enhanced by choosing a Zebron™ PLUS liner with quartz wool. Liners packed with wool can prevent non-volatile compounds from entering the column and improve sample vaporization for a more robust, reproducible analysis.
Manufacturer information: Zebron Z-Guard™ GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
Specifications for Zebron Z-Guard Metal Guard Column
| Manufacturer | Phenomenex |
| GC Phase | Z-Guard Metal Guard Column |
| GC Length (m) | 5 |
| GC Internal Diameter (mm) | 0.53 |
| GC Film Thickness (µm) | N/A |
| GC Format | Guard Column |
| GC Option | Standard |