Zebron ZB-FAME GC Columns
تسريع اختبار FAME
الشروط والأحكام
30-day money-back guarantee
Shipping: 2-3 Business Days
Zebron ZB-FAME GC Columns
عمود GC السريع لتحليل FAME
- تقليل زمن تشغيل فصل FAMEs التقليدي حتى 75%
- فصل متماكبات FAME من نوع cis/trans بدقة Rs ≥ 1.0
- انتقائية سيانوبروبيل عالية مقبولة للاستخدام مع طرق AOCS وAOAC وIOC
ملاحظات تطبيقية:
- Reproducible FAME Analysis on a 100 meter Zebron™ ZB-FAME GC Column. Read more.
- Demonstration of Robustness and Selectivity for the Analysis of FAMEs in Salmon Oil and Pet Food. Read more.
الاستخدام الموصى به
استرات الأحماض الدهنية الميثيلية (FAMEs)، متماكبات cis/trans، أحماض أوميجا 3 وأوميجا 6
نظرة عامة
Upgrade to Zebron from any high cyanopropyl phase:
Agilent® | Supelco® |
|---|---|
| CP-Sil 88 | SP®-2380 |
| HP-88 | SP-2560 |
DB®-23 |
Accelerating FAME Testing
Designed to move beyond the conventional to the exceptional , Zebron GC columns come to life through a coupling of innovative spirit and technical excellence. As part of the Zebron Unlimited series of columns, Zebron ZB FAME offers unparalleled performance through the power of targeted selectivity when analyzing fatty acid methyl esters (FAMEs)
Optimized High-Cyano Polarity
FAME separations require the use of high polarity columns for adequate resolution of cis/trans isomers. Zebron™ ZB-FAME is an optimized high-cyanopropyl (G48) chemistry that provides the polarity that you need, while remaining compatible with AOAC, OCS, and IOC regulatory methods.
ترتيب الشطف لمعيار 37 FAME
Peak | Compound | ID |
|---|---|---|
| 1 | Butanoic Acid Methyl Ester | C4:0 |
| 2 | Hexanoic Acid Methyl Ester2 | C6:0 |
| 3 | Octanoic Acid Methyl Ester | C8:0 |
| 4 | Decanoic Acid Methyl Ester | C10:0 |
| 5 | Undecanoic Acid Methyl Ester | C11:0 |
| 6 | Dodecanoic Acid Methyl Ester | C12:0 |
| 7 | Tridecanoic Acid Methyl Ester | C13:0 |
| 8 | Myristic Acid Methyl Ester | C14:0 |
| 9 | Myristoleic Acid Methyl Ester | C14:1 cis 9 |
| 10 | Pentadecanoic Acid Methyl Ester | C15:0 |
| 11 | cis-10-Pentadecenoic Acid Methyl Ester | C15:1 cis 10 |
| 12 | Hexadecanoic Acid Methyl Ester | C16:0 |
| 13 | Palmitoleic Acid Methyl Ester | C16:1 cis 9 |
| 14 | Heptadecanoic Acid Methyl Ester | C17:0 |
| 15 | cis-10-Heptadecenoic Acid Methyl Ester | C17:1 cis 10 |
| 16 | Stearic Acid Methyl Ester | C18:0 |
| 17 | Elaidic Acid Methyl Ester | C18:1 trans 9 |
| 18 | Oleic Acid Methyl Ester | C18:1 cis 9 |
| 19 | Linolelaidic Acid Methyl Ester | C18:2 trans 9,12 |
Peak | Compound | ID |
|---|---|---|
| 1 | Linoleic Acid Methyl Ester | C18:2 cis 9,12 |
| 2 | γ-Linolenic Acid Methyl Ester | C18:3 cis 6,9,12 |
| 3 | α-Linolenic Acid Methyl Ester | C18:3 cis 9,12,15 |
| 4 | Arachidic Acid Methyl Ester | C20:0 |
| 5 | cis-11-Eicosenoic Acid Methyl Ester | C20:1 cis 11 |
| 6 | cis-11,14-Eicosadienoic Acid Methyl Ester | C20:2 cis 11,14 |
| 7 | Heneicosanoic Acid Methyl Ester | C21:0 |
| 8 | cis-8,11,14-Eicosatrienoic Acid Methyl Ester | C20:3 cis 8,11,14 |
| 9 | Arachidonic Acid Methyl Ester | C20:4 cis 5,8,11,14 |
| 10 | cis-11,14,17-Eicosatrienoic Acid Methyl Ester | C20:3 cis 11,14,17 |
| 11 | Behenic Acid Methyl Ester | C22:0 |
| 12 | Erucic Acid Methyl Ester | C22:1 cis 13 |
| 13 | cis-5,8,11,14,17-Eicosapentaenoic Acid Methyl Ester | C20:5 cis 5,8,11,14,17 |
| 14 | cis-13,16-Docosadienoic Acid Methyl Ester | C22:2 cis 13,16 |
| 15 | Tricosanoic Acid Methyl Ester | C23:0 |
| 16 | Lignoceric Acid Methyl Ester | C24:0 |
| 17 | Nervonic Acid Methyl Ester | C24:1 cis 15 |
| 18 | cis-4,7,10,13,16,19-Docosahexaenoic Acid Methyl Ester | C22:6 cis 4,7,10,13,16,19 |
QC Tested For FAMEs
Baseline Separation of Common Isomers
Food and dietary standards require separation of cis/trans fatty acids. Zebron™ ZB-FAME is able to separate from C4 to C24 with resolution of specific cis/trans fatty acids.
Completely Resolve AOAC Critical Pairs
Columns: | Zebron ZB-FAME |
Dimension: | 30 meter x 0.25 mm x 0.20 µm |
Detector: | FID @ 260 °C |
Part No.: | 7HG-G033-10 |
Injection: | Split 50:1 @ 240 °C, 1 µL |
Recommended Liner: | Zebron PLUS Single Taper with Wool |
Liner Part No.: | AG2-0A11-05 (for Agilent® systems) |
Carrier Gas: | Helium @ 1.2 mL/min (constant flow) |
Oven Program: | 100 °C for 2 min to 140 °C @ 10 °C/minto 190 °C @ 3 °C/min to 260 °C @ 30 °C/min for 2 min |
Sample:
37 FAME standard
Separate Detailed C18 Compounds
Due to regulatory guidelines around trans fat content in food, detailed analysis of specific FAMEs isomers is commonly performed. The below methods demonstrate this testing using a 60 meter Zebron™ ZB-FAME column.
Analysis of C18:1, C18:2, and C18:3
Columns: | Zebron ZB-FAME |
Dimension: | 60 meter x 0.25 mm x 0.20 µm |
Detector: | FID @ 260 °C |
Part No.: | 7KG-G033-10 |
Injection: | Split 50:1 @ 240 °C, 1 µL |
Recommended Liner: | Zebron PLUS Single Taper with Wool |
Liner Part No.: | AG2-0A11-05 (for Agilent® systems) |
Carrier Gas: | Helium @ 30 cm/sec (constant flow) |
Oven Program: | 160 °C (isothermal) |
Sample:
As listed. For full peak identification, visit www.phenomenex.com/DetailedFAME
Twice The Runs, Half The Time
37 من استرات الأحماض الدهنية (FAMEs) في تشغيل قصير مدته 11 دقيقة
Traditionally, cis/trans FAME separations require the use of long (100 meters or more) columns and can run up to 60 minutes, resulting in a bottleneck to higher productivity. Zebron™ ZB-FAME provides targeted selectivity that allows for reduced column length – run times as short as 11 minutes without compromising your results!
Columns: | Zebron ZB-FAME |
Dimension: | 20 meter x 0.18 mm x 0.15 μm |
Detector: | FID @ 260 °C |
Part No.: | 7FD-G033-05 |
Injection: | Split 100:1 @ 250 °C, 1 µL |
Recommended Linear: | Zebron PLUS Single Taper Z-Liner™ |
Liner Part No.: | AG2-0A13-05 (for Agilent® systems) |
Carrier Gas: | Helium @ 1.0 mL/min (constant flow) |
Oven Program: | 80 °C for 1.5 min to 160 °C @ 40 °C/min to 185 °C @ 5 °C/min to 260 °C @ 30 °C/min |
Sample:
37 FAME standard
المستندات
- Guide: GC Troubleshooting Quick Reference Guide
- Technical Notes: Fast Analysis of 37 FAMEs in 11 Minutes Using a Zebron ZB-FAME GC Column
- Technical Notes: 37 FAMEs In Under 25 Minutes by GC/FID Using Zebron ZB-FAME
- Technical Notes: Optimized Column Selectivity for Orthogonal Separation of Fatty Acid Methyl Esters (FAMEs) Using GCxGC (TN-2064)
- Technical Notes: FAMEs In Peanut Butter by GC/FID Using Zebron ZB-FAME
- Technical Notes: FAMEs In Monterey Jack Cheese by GC/FID Using Zebron ZB-FAME
- Technical Notes: Robust FAME Analysis in Salmon Oil & Pet Food with Zebron ZB-FAME Column
- Supporting Docs: Zebron Gas Filter User Guide
- Guide: Zebron GC Column Selection Chart
- Supporting Docs: Zebron Gas Filter Selection Tool
- Brochures: Zebron Gas Management Brochure
- Guide: Analyzing Fats and Oils by GC
الأسئلة الشائعة
هل يمكنني تعبئة أو إعادة تعبئة بطانة GC بالصوف بنفسي؟
رغم أن التكلفة المبدئية لتعبئة البطانة بنفسك قد تبدو مغرية، فإن الوقت والمتاعب الناتجة عن ذيل القمم أو عدم تكرارها قد تكون كبيرة! فألياف الصوف المعبأة يدويًا تنكسر غالبًا أثناء التركيب، وقد تُخدش طبقة التخميل الموجودة على البطانة أو تتلف، خصوصًا عند إزالة الصوف أو إعادة تعبئته. وعند إدخال الصوف أو إخراجه بالقوة قد تكشف هذه الخدوش مواقع نشطة فيظهر ذيل القمم وتضعف التكرارية. أما بطانات Zebron PLUS المعبأة مسبقًا فتمر بعملية التخميل والصوف في مكانه، فلا تنكشف أي مواقع نشطة تتكون أثناء التعبئة، كما أن تغليفها الجديد الذي لا يحتاج لمس وحلقة O-ring المركّبة مسبقًا يمنعان التلوث أثناء التركيب.
هل تطيل بطانة Zebron PLUS بالصوف عمر عمود GC؟
نعم. بطانات Zebron PLUS معبأة بصوف الكوارتز الذي له وظيفتان: أ) يساعد على التبخير المتجانس للمواد والمذيب في المدخل لنقلها بفعالية إلى رأس عمود GC. ب) يعمل كفلتر يحتجز الشوائب غير المتطايرة ويمنعها من الدخول إلى عمود GC.
أعمل بعينات متسخة تترك بقايا على بطانة GC بعد حوالي 100 حقنة. هل يمكنني تنظيف البطانة بالفرك أو بالموجات فوق الصوتية وإعادة استخدامها؟
لا يُنصح بفرك البطانات أو تنظيفها بالموجات فوق الصوتية. فتكوّن البقايا يدل على تلوث، وتحديدًا على وجود شوائب غير متطايرة في العينة، وفي هذه الحالة يُنصح باستبدال البطانة بدلًا من تنظيفها. فالموجات فوق الصوتية قد تغيّر طبقة التخميل، والفرك قد يسبب خدوشًا ومواقع نشطة، فتظهر مشاكل كروماتوجرافية مثل ضعف القياس الكمي وتكسّر المواد وضعف التكرارية وعدم تماثل القمم.
هل يمكنني الحصول على مساعدة فورية في طريقتي الحالية أو القادمة؟
بالتأكيد، نحن هنا دائمًا للمساعدة! تواصل معنا عبر واتساب أو صفحة «اتصل بنا» وسنساعدك بتوصيات الطرق والنصائح.
أستخدم عمود GC خاملًا ومع ذلك أرى ذيلًا في القمم، ما السبب؟
لتحليل المركبات النشطة، من الضروري استخدام عمود عالي الخمول وبطانة (Liner) عالية الخمول. فالبطانة هي أول مكان قد تتداخل فيه المواد المحللة أثناء تحليل GC، ومن المهم ألا تُمتز عليها. وتمر بطانات Zebron PLUS بعملية تخميل صارمة وتُختبر للتأكد من خمولها لضمان نتائج موثوقة مع المركبات شديدة النشاط مثل الأحماض غير المشتقة والقواعد النشطة.
عند مواجهة مشاكل في القمم أو الدقة في تحليل GC، من أين أبدأ؟
المدخل هو المكان الأكثر شيوعًا لحدوث المشاكل في كروماتوجرافيا الغاز لأن: • المدخل يتعرض لدرجات حرارة عالية جدًا. • يحتوي على عدة مستهلكات تحتاج صيانة دورية. • بعض أنماط الحقن مثل الحقن بدون تقسيم (Splitless) عملية بطيئة، فقد تتداخل المواد المستهدفة مع المدخل قبل دخول العينة إلى العمود.
هل يمكنكم ترشيح بطانة GC مناسبة لتحليل العينات المتسخة أو العينات ذات نقاط الغليان أو الأوزان الجزيئية المتباعدة؟
يمكن تحسين تحليل العينات المتسخة أو ذات نقاط الغليان أو الأوزان الجزيئية المتباعدة باختيار بطانة Zebron™ PLUS بصوف الكوارتز. فالبطانات المعبأة بالصوف تمنع المركبات غير المتطايرة من دخول العمود وتحسّن تبخير العينة لتحليل أقوى وأكثر تكرارية.
Manufacturer information: Zebron ZB-FAME GC Columns – Phenomenex (USA). MAS Brand is the official representative of Phenomenex in Egypt.
المواصفات Zebron ZB-FAME GC Columns
| GC Length (m) | 20 أو 30 أو 60 أو 100 |
| GC Internal Diameter (mm) | 0.18 أو 0.25 |
| GC Film Thickness (µm) | 0.15 أو 0.2 |
| GC Format | Capillary Column أو 5-inch Cage |
| GC Option | Standard أو w/ GUARDIAN 5 m |
| Manufacturer | Phenomenex |
| GC Phase | ZB-FAME |